Description
The S13362 series can reduce dark count by cooling in addition to low afterpulses and low crosstalk of the S13360 series. The S13362 series integrates the S13360 series with thermoelectric cooler. The photosensitive area is available in two sizes of 1.3 × 1.3 mm and 3.0 × 3.0 mm.
Features
– Significantly reduced crosstalk
– Low afterpulses
– Superior photon counting capability
– Low voltage (VBR=51.1 V typ.) operation
– High gain: 105 to 106
– Low dark count (no more than 1/20 the count at normal temperature through cooling)
– Operates with simple readout circuit
Specifications
Package type | Metal (TO-8) |
---|---|
Number of channels | 1 ch |
Effective photosensitive area / ch | 1.3 × 1.3 mm |
Number of pixels /ch | 667 |
Pixel size | 50 μm |
Spectral response range | 320 to 900 nm |
Peak sensitivity wavelength (typ.) | 450 nm |
Dark count/ch (typ.) | 5 kcps |
Terminal capacitance/ch (typ.) | 60 pF |
Gain (typ.) | 1.7×106 |
Measurement condition | Ta=25 ℃ |